Construction Specialties

Proteção de paredes | Coberturas de juntas de dilatação | Tapete de entrada

+44 (0)1296 652800
Menu
  • Página Inicial
  • Produtos
    • Acrovyn® Wall & Door Protection
      Acrovyn® Wall & Door Protection
      Portas e proteção de portas Acrovyn®
      Portas e proteção de portas Acrovyn®
      Coberturas de parede à medida Acrovyn by Design®
      Coberturas de parede à medida Acrovyn by Design®
      Coberturas de juntas de dilatação Couvraneuf®
      Coberturas de juntas de dilatação Couvraneuf®
      Tapete de entrada Pedisystems®
      Tapete de entrada Pedisystems®
      Exterior Solar Shading
      Exterior Solar Shading
  • Markets
    • Serviços de saúde
      Serviços de saúde
      Educação
      Educação
      Comércio a retalho
      Comércio a retalho
  • Inspiração
    • Projetos
    • Blog
    • Designing Spaces for Wellbeing
  • Recursos
    • Brochuras
      Brochuras
      Setores do mercado
      Setores do mercado
      CPD Seminars
      CPD Seminars
  • Sobre nós
  • Contacto
  • Careers

PL-4080 Ventilation Louvres

  • PL-4080
  • 3D VIEW

PL-4080

3D VIEW

Concealed behind an attractive perforated skin, Perform PL-4080 louvres offer good airflow and weather performance.

nulo
nulo

ENTRY

nulo

DISCHARGE

Classifications based on testing to EN 13030.

Features & Advantages

  • Wide-pitched extruded blades for good airflow performance
  • Perforated aluminium face conceals the louvre while offering modern appearance
  • Louvre module is powder-coated in matt black as standard, for maximum concealment
  • Supplied to site as pre-fabricated modules, for efficient installation
  • Sightproof design
View 3D Model
Download Datasheets
View Test Data

Specification Calculators

We've built 2 tools to help you with your specification process. One to help you calculate pressure drop for your chosen CS Louvre model, the other to help you calculate the area of louvre required for your project.
Pressure Drop Calculator
Louvre Area Calculator

KEY FEATURES

  • Blade orientation: Horizontal
  • Joint options:
    • Perforated sheet: invisible joints
    • Louvre modules: positioned behind perforated sheet; mullions are interlocking
  • Louvre depth: 191 mm (standard and glazing frame)
  • Blade pitch: 100 mm
  • Weight: 21 kg/m2, based on a 2 m x 2 m module size
  • Maximum module dimensions (based on 1.5 kPa wind load):
    • Max width: 3600 mm*
    • Max height: 3600 mm*
      * Maximum unit weight: 150 kg, including accessories. Site access and lifting capability should be assessed prior to specification and installation.

Download Technical Datasheet for detailed drawings.

Download Technical Datasheet

PERFORMANCE

EN 13030
  • Airflow Class: 3 (entry & discharge)
  • Airflow Coefficient Ce (entry): 0.260
  • Airflow Coefficient Cd (discharge): 0.253
  • Wind-Driven Rain Performance Class:
    • 13 m/s, 75 mm/hr = C up to 3.0 m/s
EN 13030 Performance Datasheet

Weather considerations:
Perform Louvres are not suitable for use in areas where perforations may become blocked or clogged with snow, ice, debris, or other occlusions. To maximise their performance, prevent property damage and provide a safe environment, they should be inspected and maintained regularly.

MATERIALS & FINISHES

MATERIALS
  • Perforated sheet:
    • 3mm thick aluminium alloy 1050 H14/H24 as standard.
    • Perforation pattern: 9.5mm Ø holes, with 12.7mm staggered centres and pitch.
  • Louvres:
    • Aluminium alloy 6063-T6.
    • Nominal thickness: 1.73 mm and 1.98 mm for blades, 2.54 for head, cill and jamb frames, and for mullions
FINISH OPTIONS
  • Louvres: powder-coated matt black as standard
  • Perforated sheet:
    • Mill finish aluminium
    • Clear or colour anodised
    • Polyester powder-coated – matt (standard) or gloss

OPTIONAL EXTRAS

  • Cill pan
  • Head / cill / jamb cover plates
  • Bird / vermin guards – galvanised weld mesh (standard) or expanded aluminium
  • Insect mesh
  • Blanking – single-skin plates or insulated panels
  • Louvred doors and gates
  • Dampers
View all accessories

PROJECTS

View All Louvre Projects

Especificações

Guidance

The principal reason for using louvres is to allow the movement of air. But, louvre specification is a balance between form and function, with louvred façade appearance playing an important part in the selection process.

  • Louvre Specification Calculators
  • Performance Considerations
  • Design Considerations
  • Weather Louvre Testing
Learn more

Louvres

What's in the brochure
  • - Industry Leading Products
  • - Innovative New Design Options
  • - Detailed Technical Information
  • - Louvre Specification Guidance

+44 (0)1296 652800
sales@c-sgroup.co.uk
Solicitar uma amostra
Pedir cotação
Obter ajuda técnica

Menu

  • Produtos CS
  • Projetos
  • Blog
  • Sobre nós
  • Contact Us
  • Pick Country

Contacto

Construction Specialties UK Ltd
1010 Westcott Venture Park
Westcott, Bucks, HP18 0XB
Reino Unido
Obter direções
Tel.: +44 (0)1296 652800
Fax: +44 (0)1296 652888
Endereço eletrónico: sales@c-sgroup.co.uk

Confidencialidade

This website uses cookies to help us give you the best experience when you visit our website. By continuing to use this website, you consent to our use of these cookies. Find out more about how we use cookies and how to manage them below in our privacy policy.
Privacy Policy

Copyright © 2026 · Construction Specialties

Copyright © 2026 · Genesis Framework · WordPress · Log in